The SGZ-200BS Portable turbidity meter is designed for turbidity measurement in accordance with international turbidity measurement standards ISO7027, and provides measurements in traditional unit of NTU, EBC, ASBC.
The instrument widely apply to the turbidity measurement in power plants, waterworks, life sewage treatment plants, drink factories, environment protection department, process water, brewage and drug manufactures departments, hospitals and so on.
★ The large bright LCD makes the reading more comfortable, effective avoid natural light influence.
★ The succinct operation, broad measuring range and high cost performance ratio, can suit to various professional applications.
★ The unique localization structure and high accuracy optical path system effectively guarantee the measuring value correctness and repeatability.
★ Low drift, high accuracy, stable circuitry system and high effective longevity light source all ensure the instrument running stable and long time.
★ Low consumption and AC/DC power supply, compact design easier for operating outside or laboratory.
★ With low voltage indication function remand of users to replace battery timely to ensure the measuring value accuracy and effectively.
Product model |
SGZ-200BS |
Principle of measurement |
90° Scattered light |
Resolution (NTU) |
0.1 |
Measuring range (NTU) |
0~200 |
Zero drift |
±1.5%F.S (NTU/30min) |
Indication Stability |
±1.5%F.S (NTU/30min) |
Repeatability |
≤2% |
Basic accuracy |
±6% |
Power supply oscillation influence |
0.5%F.S |
Power requirement |
DC 6V (4×1.5V Battery) |
Storage requirement |
Temperature 0~45ºC, humidity<85% |
Note: 1 EBC=4 NTU (EBC European Brewing Industry Turbidity Unit)
1 ASBC=0.058 NTU (ASBC American Brewing Industry Turbidity Unit)
Instrument Principle.
This instrument is compared with measured solution and standard calibration solution and it based on the principle of color intensity values. After placed measured solution in the measuring cell, light resource issued by a particular light beam and in face of the dissolved substances simultaneously, a part of beam is absorbed (Absorbance=light source total flux-the amount of light through), then it will as a signal of circuit apparatus of receiving, amplification, derived from the value after treatment and then compared with the standard solution.
Model Difference.
This product is widely used for turbidity measurement in power plants, water purification plants, waterworks, domestic sewage treatment plants, beverage plants, environmental protection departments, industrial water, liquor and pharmaceutical industries, epidemic prevention departments, hospitals and other departments
Q1. How can I choose the suitable one?
Please tell us your detailed requirements by mail or online, we will recommend the suitable one as your request.
Q2. How can I pay?
We accept many payment term, such as T/T, Western Union…
Q3. When I receive it after pay?
Normal models can be delivered with 5-7days, please contact us to check transport time to your address.
Q4. What should I do if I do not know how to use?
Manual user will be sent together, you can also contact us with more technological support.
Q5. What should I do if some parts broken?
We do standard export package and 1 year warranty except wear parts.